For the interface area containing only the microwire, the astrocy

For the interface area containing only the microwire, the astrocyte RI for LPS coated wire (RI = 3.33) was significantly higher than PEG coated

and LPS + PEG coated wire (PEG RI = 2.59, p = 0.015; LPS + PEG RI = 2.63, p = 0.02). For the interface area containing the wire and extending an adjacent 25 μm, the same pairwise difference were observed, but with a stronger difference Salinomycin clinical trial between the LPS coated wire (RI = 6.7) and the LPS + PEG coated wire (PEG RI = 5.75, p = 0.012; LPS + PEG RI = 5.64, p = 0.0045). For the interface area containing the microwire and extending an adjacent 50 μm, the same observation of the LPS astrocyte RI being higher than both PEG and LPS + PEG was noticed (LPS RI = 7.54, PEG RI = 6.49, p = 0.02; LPS + PEG RI = 6.19, p = 0.002). Overall the astrocytes show a similar pattern in the interface as the microglia, but to a lesser extent. Importantly, for all three interface sizes (at the wire, within 25 μm of the wire, and within 50 μm of the wire), the PEG coating is able to significantly reduce the LPS-induced astrocyte response. Figure 4 Astrocytes in interface areas of varying width exhibit a tiered response to microwires coated with PEG, with or without LPS. Figure ​Figure55 shows the astrocyte RI at

distant areas. No significant differences were observed between the different treatments for the closest distant bin extending from 50 to 150 μm from edge of microwire. For the middle two distant bins, a slightly significant difference was observed between LPS coated wire and LPS + PEG coated wire [bin 2 (150–250 μm from edge of wire): LPS RI = 2.31, LPS + PEG RI = 1.37, p = 0.012; bin 3 (250–350 μm from edge of wire): LPS RI = 2.73, LPS + PEG RI = 1.73, p = 0.03]. Figure 5 Differences in astrocyte

responses in distant areas appear between LPS and LPS + PEG coated microwires at the middle of the distance range analyzed. Neurons Figures ​Figures6,6, ​,77 show the neuron RI in interface and distant regions respectively. No significant differences in the neuron response were found between any of the treatment conditions in either interface or distant region. In contrast to microglia and astrocytes, where the RI was higher in distant areas in comparison to the widest interface area examined, the neuron RI in distant Drug_discovery areas was roughly equal to that in the widest interface area examined. Figure 6 No differences are observed in neuronal responses in interface areas of various widths. Figure 7 No differences are observed in neuronal responses in distant areas. Discussion Validity of model system To test the effects of a dip coated PEG film on the cellular responses to implanted electrodes, we modified a robust and frequently replicated in vitro mixed cortical culture model pioneered by Polikov et al. (2006, 2009, 2010; Achyuta et al., 2010; Tien et al., 2013).

Leave a Reply

Your email address will not be published. Required fields are marked *

*

You may use these HTML tags and attributes: <a href="" title=""> <abbr title=""> <acronym title=""> <b> <blockquote cite=""> <cite> <code> <del datetime=""> <em> <i> <q cite=""> <strike> <strong>